Commercial & industrial only. We do not install residential systems. Serving the GTA and within 100 km of Toronto · 1.416.791.9519
SecurityStores Call 1.416.791.9519
Card Access Control · Pickering

Card Access Control in Pickering

Most card access installed in Canada still runs 125 kHz proximity cards over unencrypted Wiegand wiring. Both were designed before cloning hardware cost thirty dollars. The system logs every entry accurately and stops nobody who has spent an afternoon on the internet.

Speak to an engineer, not a call centre.
20+years in the field
500+systems deployed
24/7monitoring available
Canadiansupport

Request a site assessment

Commercial and industrial sites only. We reply the same business day.
Interested in
Or call 1.416.791.9519 and speak to someone now.
HomeLocationsPickering › Card Access Control
Commercial office towers
REC 00:00:00
CAM 01Building Entrance
Local conditions

Access control for Pickering sites

Pickering's employment profile is shaped by the energy sector and its supply chain, which brings a level of procedural rigour that most commercial sites do not have. Suppliers into that chain frequently inherit documentation, access-logging and audit requirements from their customer, and a system that cannot produce a clean access record on demand becomes a commercial problem rather than a security one.

What that means for Access control

Energy supply chain tenancies carry inherited audit and access-record requirements. Establish what the customer contract mandates before specifying.

Employment areas we work in around Pickering: Brock Industrial, Pickering Innovation Corridor, Bayly Street employment lands.

Credential technology, honestly rated

The card in the employee's wallet is the whole security model. This is the part of an access system vendors are least eager to discuss.

CredentialFrequencySecurityVerdict
Prox (HID Prox, EM4100)125 kHzNone — no encryption, static numberCloned in seconds. Do not specify.
MIFARE Classic13.56 MHzCrypto-1, publicly broken since 2008Legacy only. Plan a migration.
MIFARE DESFire EV2/EV313.56 MHzAES-128, mutual authenticationCurrent standard for new work.
Seos and equivalent13.56 MHzAES, credential-level keysHigh-security and multi-site.
Mobile (BLE/NFC)Device-bound, revocable instantlyStrong, where phone policy allows.

What we do

Detail that changes the outcome

Fail-safe, fail-secure, and getting out of the building

Fail-safe hardware unlocks when power is lost; fail-secure stays locked. Magnetic locks are inherently fail-safe, electric strikes are usually fail-secure. The choice is not a preference — it is governed by the means-of-egress provisions of the Ontario Building Code and the Fire Code, and electromagnetic locks on egress doors carry specific requirements around release on fire alarm and on loss of power. Have the door schedule reviewed by the authority having jurisdiction before hardware is ordered, not after it is installed.

What access control is actually for

The deterrent value is real but modest. The operational value is larger and much less discussed: knowing who was in the building at 2 a.m., closing out a terminated employee in thirty seconds across every door and every site, and producing an entry record alongside video when an incident is disputed. Systems specified only against intruders tend to disappoint. Systems specified against disputes tend to pay for themselves.

Wiegand versus OSDP

Wiegand is a one-way, unencrypted, unsupervised protocol from the 1980s. Anyone who can reach the wiring behind a reader can capture credentials or inject a valid one, and the panel cannot tell that a reader has been removed. OSDP — SIA's open protocol, also published as IEC 60839-11-5 — runs two-way over RS-485 with AES-128 Secure Channel and supervises the reader, so a tampered or disconnected reader raises an alarm. New installations should be OSDP. Existing Wiegand can usually be converted reader by reader rather than all at once.

Pickering employment areas

Brock IndustrialPickering Innovation CorridorBayly Street employment lands

Other systems in Pickering

Access control in Pickering

Our Prox cards work fine. Why change?

They work exactly as well for someone standing near your employee in a parking lot. A 125 kHz proximity card broadcasts a static number with no encryption, and copying one takes a cheap handheld and a few seconds of proximity. If the doors matter, the credential is where to spend.

Do we have to replace every reader at once?

No. Most migrations run in stages — multi-technology readers accept both old and new credentials during the transition, so cards can be reissued over months and doors converted by priority.

Can access control and cameras work together?

Yes, and it is the single most useful integration available. Every badge event, forced door and held door gets the matching clip attached, which turns a log line into evidence and removes a search that otherwise takes an hour.

Why does Pickering need a different approach?

Energy supply chain tenancies carry inherited audit and access-record requirements. Establish what the customer contract mandates before specifying. Pickering's employment profile is shaped by the energy sector and its supply chain, which brings a level of procedural rigour that most commercial sites do not have.

Access control nearby

All security systems in Pickering →