Commercial & industrial only. We do not install residential systems. Serving the GTA and within 100 km of Toronto · 1.416.791.9519
SecurityStores Call 1.416.791.9519
Card Access Control · Cambridge

Card Access Control in Cambridge

Most card access installed in Canada still runs 125 kHz proximity cards over unencrypted Wiegand wiring. Both were designed before cloning hardware cost thirty dollars. The system logs every entry accurately and stops nobody who has spent an afternoon on the internet.

Speak to an engineer, not a call centre.
20+years in the field
500+systems deployed
24/7monitoring available
Canadiansupport

Request a site assessment

Commercial and industrial sites only. We reply the same business day.
Interested in
Or call 1.416.791.9519 and speak to someone now.
HomeLocationsCambridge › Card Access Control
Commercial office towers
REC 00:00:00
CAM 01Building Entrance
Local conditions

Access control for Cambridge sites

Cambridge is an automotive manufacturing centre, and the tier-one and tier-two suppliers clustered around it operate under customer security requirements that are frequently more demanding than anything the business would specify for itself. Intellectual property protection around tooling and process is a real concern, which puts weight on interior access control and on knowing precisely who was in a given area at a given time.

What that means for Access control

OEM-imposed security requirements and process IP protection. Interior zone control and access audit trails usually outrank perimeter coverage.

Employment areas we work in around Cambridge: Cambridge Business Park, Boxwood Business Park, Franklin Boulevard corridor, Hespeler industrial.

Credential technology, honestly rated

The card in the employee's wallet is the whole security model. This is the part of an access system vendors are least eager to discuss.

CredentialFrequencySecurityVerdict
Prox (HID Prox, EM4100)125 kHzNone — no encryption, static numberCloned in seconds. Do not specify.
MIFARE Classic13.56 MHzCrypto-1, publicly broken since 2008Legacy only. Plan a migration.
MIFARE DESFire EV2/EV313.56 MHzAES-128, mutual authenticationCurrent standard for new work.
Seos and equivalent13.56 MHzAES, credential-level keysHigh-security and multi-site.
Mobile (BLE/NFC)Device-bound, revocable instantlyStrong, where phone policy allows.

What we do

Detail that changes the outcome

Wiegand versus OSDP

Wiegand is a one-way, unencrypted, unsupervised protocol from the 1980s. Anyone who can reach the wiring behind a reader can capture credentials or inject a valid one, and the panel cannot tell that a reader has been removed. OSDP — SIA's open protocol, also published as IEC 60839-11-5 — runs two-way over RS-485 with AES-128 Secure Channel and supervises the reader, so a tampered or disconnected reader raises an alarm. New installations should be OSDP. Existing Wiegand can usually be converted reader by reader rather than all at once.

Fail-safe, fail-secure, and getting out of the building

Fail-safe hardware unlocks when power is lost; fail-secure stays locked. Magnetic locks are inherently fail-safe, electric strikes are usually fail-secure. The choice is not a preference — it is governed by the means-of-egress provisions of the Ontario Building Code and the Fire Code, and electromagnetic locks on egress doors carry specific requirements around release on fire alarm and on loss of power. Have the door schedule reviewed by the authority having jurisdiction before hardware is ordered, not after it is installed.

What access control is actually for

The deterrent value is real but modest. The operational value is larger and much less discussed: knowing who was in the building at 2 a.m., closing out a terminated employee in thirty seconds across every door and every site, and producing an entry record alongside video when an incident is disputed. Systems specified only against intruders tend to disappoint. Systems specified against disputes tend to pay for themselves.

Cambridge employment areas

Cambridge Business ParkBoxwood Business ParkFranklin Boulevard corridorHespeler industrial

Other systems in Cambridge

Access control in Cambridge

Our Prox cards work fine. Why change?

They work exactly as well for someone standing near your employee in a parking lot. A 125 kHz proximity card broadcasts a static number with no encryption, and copying one takes a cheap handheld and a few seconds of proximity. If the doors matter, the credential is where to spend.

Do we have to replace every reader at once?

No. Most migrations run in stages — multi-technology readers accept both old and new credentials during the transition, so cards can be reissued over months and doors converted by priority.

Can access control and cameras work together?

Yes, and it is the single most useful integration available. Every badge event, forced door and held door gets the matching clip attached, which turns a log line into evidence and removes a search that otherwise takes an hour.

Why does Cambridge need a different approach?

OEM-imposed security requirements and process IP protection. Interior zone control and access audit trails usually outrank perimeter coverage. Cambridge is an automotive manufacturing centre, and the tier-one and tier-two suppliers clustered around it operate under customer security requirements that are frequently more demanding than anything the business would specify for itself.

Access control nearby

All security systems in Cambridge →